HemoCue 201 DM systems bring modern data management capabilities to the HemoCue product line. Available for both hemoglobin and glucose testing, they offer healthcare providers faster data availability, better quality control, increased regulatory compliance and improved administration. HemoCue 201 DM systems allow healthcare providers to ensure the authorized and appropriate use of HemoCue analyzers. By means of a wide range of settings and definable options, the systems can be made to prompt the operator for identification, lot numbers, quality control and other required information during analysis. This data is then transmitted to clinical information systems, which leads to improved staff and patient management and to more effective billing. |
 |
|
|
 |
 |
| • |
 |
Systems for hemoglobin and glucose |
 |
| • |
 |
Full connectivity possible |
 |
| • |
 |
Compliance with CLSI POCT1-A (CIC standard) |
 |
|
 |
 |
 |
 |
|
 |
 |
| • |
 |
Analyzer |
 |
| • |
 |
Docking station (primary and secondary) |
 |
| • |
 |
Microcuvettes |
 |
|
 |
 |
 |
 |
|
 |
 |
| • |
 |
Network (LAN/WAN) |
 |
| • |
 |
USB |
 |
|
 |
 |
 |
 |
|
 |
 |
| • |
 |
Operator ID input (access denied if ID not recognized) |
 |
| • |
 |
Patient ID input |
 |
| • |
 |
Lab Number input |
 |
| • |
 |
Cuvette Batch data input |
 |
| • |
 |
Password protection |
 |
| • |
 |
QC Control with input of lot numbers and range (plus lockout functions and reminder time) |
 |
| • |
 |
Linearity and proficiency testing |
 |
| • |
 |
STAT tests |
 |
| • |
 |
Critical value alert |
 |
|
 |
 |
 |
 |
|
 |
 |
| • |
 |
Easy-to-use touch display |
 |
| • |
 |
Built-in barcode scanner |
 |
| • |
 |
Infrared transmitter (for data transfer to docking station) |
 |
| • |
 |
Stores 4 000 Patient/STAT tests, 500 QC tests and 500 Analyzer logs |
 |
| • |
 |
w 6.79in / h 3.66in / d 1.97in |
 |
| • |
 |
0.77 lbs with battery |
 |
|
 |
 |
 |
 |
|
 |
 |
| • |
 |
Network communication with a pre-defined destination (PC or Data Management Server) via the primary docking station |
 |
| • |
 |
Recharges analyzer battery while analyzer is docked |
 |
| • |
 |
Allows measurements to be performed while analyzer is docked |
 |
| • |
 |
Up to 4 secondary docking stations can be connected to one primary docking station |
 |
|
 |
 |
 |
 |
|
 |
 |
| • |
 |
Generate Patient and QC reports |
 |
| • |
 |
Controls analyzers remotely (LAN/WAN) |
 |
| • |
 |
Allows downloading of patient and QC data |
 |
| • |
 |
Allows changing of operator lists, control batches, etc. |
 |
| • |
 |
Allows downloading of instrument configurations |
 |
| • |
 |
Can forward measurements to host system using CLSI POCT1-A |
 |
|
 |
 |
 |
 |
|
 |